Furnace Humidifier Installation
This unique electronically pulsed flow-thru humidifier reduces water consumption by up to 80 %. The electronic controller pulses the solenoid water supply valve for a period of 4 seconds ON and 30 seconds OFF. This allows the evaporator pad to be fully saturated while drastically limiting the water wasted through the drain. This unique approach greatly improves the unit performance by allowing a higher average temperature on the evaporator pad, and makes the Pro 600 the most efficient and environmentally friendly unit. Good for homes of up to 3000 sq. ft. $178.88 Owner's Instructions for Electronically controlled FLOW-THRU Humidifier Operating and Maintenance Tips - Warranty. 1) Principle of operation 2) Adjusting the humidity level in your home A relative humidity environment of 40% is recommended. Please refer to the table on the Humidistat to help determine the proper level.
The pad is enclosed in a plastic frame with a marking that clearly indicates the bottom. It is designed to retain water before it is evaporated. The excess of water is sent to the drain.
There are two frequently encountered types of installations: LOWBOY furnace and HI-BOY furnace. Fig. 1


3) A few tips
- Do not use the supply valve (installed on the supply line) to regulate the water flow. This type of valve is designed to be completely opened or closed.
- Do not allow the drain tube to fill with water in bends, elbows or kinks. Water could accumulate in them and that could become a place for deposit buildup
4) Annual Maintenance
To replace the evaporator pad :
1- Shut off the furnace power.
2- Open the humidifier by removing the plastic screw on the side of the cover.
3- Unlock the evaporator pad by turning the little plastic retainer.
4- Remove the old pad and replace it by a new one while checking the printed marking that clearly indicates the bottom of the pad.
5- Lock the new pad in place.
6- Put the cover back and secure it with the plastic screw.
Note : Depending on the quality of water, it is recommended to replace the evaporator pad once per heating season.
5) Summer season
- If the system is used in air conditioning during the summer, reduce the air volume going through the humidifier by closing the air damper located on the side of the humidifier. The control button shows the actual position of the damper.
- It is recommended to simply shut off the humidifier system:
1- Close the water supply valve.
2- Turn the Humidistat knob to the "OFF" position.
6) Warranty
This humidifier is guaranteed against any defects in material and workmanship, under normal use, for one (1) year from the date of purchase. The frame and door are guaranteed for life against defects in material and workmanship, under normal use. This warranty applies only if the unit is properly installed and operated according to the instructions provided with this product. This warranty will not cover defects due to misuse or faulty installation. e-humidifiers will not be held responsible for any bodily injuries or damages to personal property or real estate, whether caused directly or indirectly by the humidifier. If warranty service is required during the warranty period, e-humidifiers will, at its sole discretion, repair or replace the product, without charge, upon delivery of the product where it was purchased, with proof of purchase.
7) Service
Please keep your contractor telephone number handy.