Furnace Hole Cutting

 

OPENING FOR THE HUMIDIFIER

 

furnace humidifier
furnace humidifier

WARNINGS and DISCLAIMER
The manufacturer will not be held responsible and the warranty will be void if the installer does not adhere to the following precautions.
This humidifier is a flow through model, it MUST be connected to a drain.
Installation precautions
1- This humidifier will be connected to and used under water pressure and it must be installed in such a way that if a leak occurs, the water could not cause any damage to the property. Make sure all water connections are properly installed or water spill could occur.
2- This humidifier is intended for use on forced warm air circulation furnaces, as well as multi-fuel furnaces where temperature does not exceed 180F (82C). Higher temperatures will damage your humidifier and possibly cause overflow condition and water damage to your home.
3- Do not install a humidifier where surrounding temperatures may be 32F (0C) or colder. Freezing water will damage the humidifier and burst the supply pipe, resulting in home damage.
4- Do not install the humidifier or the bypass connection directly on the furnace housing.
5- Do not install the humidifier or the bypass connection on a plenum side where a cooling coil could restrict or inhibit the airflow through the humidifier.
6- Always check that you are not about to cut or drill into any air conditioning or electrical accessories during installation.
7- Do not install a humidifier on the supply duct where the static pressure exceeds 0.4" Water Column.
8- Do not install a humidifier if the city water pressure exceeds 90 psi, water hammer could occur. Check the local codes related to pressure reduction.
9- The installation, wiring and plumbing of the humidifier must comply with national and local electrical, plumbing and building codes.
10- Electrical wiring, water supply & drain tube must not come into contact with sharp edges or hot surfaces. Please make certain the drain tube has no bends, its end placed in a floor drain and there is no resistance to the flow of the discharged water.
11- The transformer supplied is rated for 120 volts power supply. Do not connect it to a furnace supplied with another voltage.
12- Do not set the humidity lever higher than normally recommended, or condensation damage could occur.
Safety warnings
1- Please beware of sharp edges when you cut into a metal duct.
2- Always shut the power off before starting the installation. An electric shock from 120 volts could cause injury.
3- Hot water temperature higher than 125F (52C) could cause serious burns.
     Please shut off the main water supply valve before connecting the humidifier water supply.
 

furnace humidifier
furnace humidifier