WARNINGS and DISCLAIMER The manufacturer will not be held responsible and the warranty will be void if the installer does not adhere to the following precautions. This humidifier is a flow through model, it MUST be connected to a drain. Installation precautions 1- This humidifier will be connected to and used under water pressure and it must be installed in such a way that if a leak occurs, the water could not cause any damage to the property. Make sure all water connections are properly installed or water spill could occur. 2- This humidifier is intended for use on forced warm air circulation furnaces, as well as multi-fuel furnaces where temperature does not exceed 180F (82C). Higher temperatures will damage your humidifier and possibly cause overflow condition and water damage to your home. 3- Do not install a humidifier where surrounding temperatures may be 32F (0C) or colder. Freezing water will damage the humidifier and burst the supply pipe, resulting in home damage. 4- Do not install the humidifier or the bypass connection directly on the furnace housing. 5- Do not install the humidifier or the bypass connection on a plenum side where a cooling coil could restrict or inhibit the airflow through the humidifier. 6- Always check that you are not about to cut or drill into any air conditioning or electrical accessories during installation. 7- Do not install a humidifier on the supply duct where the static pressure exceeds 0.4" Water Column. 8- Do not install a humidifier if the city water pressure exceeds 90 psi, water hammer could occur. Check the local codes related to pressure reduction. 9- The installation, wiring and plumbing of the humidifier must comply with national and local electrical, plumbing and building codes. 10- Electrical wiring, water supply & drain tube must not come into contact with sharp edges or hot surfaces. Please make certain the drain tube has no bends, its end placed in a floor drain and there is no resistance to the flow of the discharged water. 11- The transformer supplied is rated for 120 volts power supply. Do not connect it to a furnace supplied with another voltage. 12- Do not set the humidity lever higher than normally recommended, or condensation damage could occur. Safety warnings 1- Please beware of sharp edges when you cut into a metal duct. 2- Always shut the power off before starting the installation. An electric shock from 120 volts could cause injury. 3- Hot water temperature higher than 125F (52C) could cause serious burns. Please shut off the main water supply valve before connecting the humidifier water supply. |